ALE XR802/XR-DC Series
1-30 kV, 6 kJ/sec, 8 kW DC

 

Description

The XR Series are low cost solutions for high performance HV Capacitor Charging applications offering extremely low pulse to pulse repeatability. The XR-DC allows continuous DC operation with low ripple, and low stored energy. Employing Lambda EMIs patented phase shifting parallel resonant converter topology the XR series supplies offers unrivalled pulse to pulse repeatability at extreme repetition rates. Unlike other manufacturers who claim high performance in data sheets, the XR series has demonstrated 0.1% pulse to pulse repeatability at repetition rates to 2kHz, in real field applications.
The XR802 shares many features with the standard 802, but in addition it is equipped with a phase shifting resonant inverter configuration which allows the charging current to be gradually reduced as the load voltage approaches the programmed level. This feature allows the XR802 supply to repetitively charge capacitive loads with pulse to pulse repeatability of 0.1% or better at repetition rates of 1kHz or more. This is a particular requirement of high performance systems where charge voltage variability results in process or dose variability and a reduction in process quality. Lambda EMI is the only power supply manufacturer currently offering this advanced performance in a compact 8kJ/sec air cooled package.

Features

  • High repeatability to better than 0.1% at repetition. rates up to 2,000 Hz
  • Air insulated output assemblies - models 1 kV to 6 kV
  • Minimum stored energy
  • Ultra fast command charge timing cycle
  • Unlimited parallel capability for higher power
  • Eliminates need for D-Qing
  • On board external divider port for super high performance
  • Remote control compatibility with Series 802 and 402
  • New high reliability cable and connector minimizes corona effects at high repetition rate.
  • Available in three configurations - Instrumented, system, and blank panel.
  • Output voltages to 50 kV
  • Up to 8000 J/sec charging time
  • 10,000 W continuous output
  • TUV safety approved

Applications

Excimer Lasers
Pulsed YAG Lasers
RF Modulators
HDTV Transmitters
Grid Bias Supplies
N2 Lasers
Dye Lasers
TEA Lasers


Specification

AC Input
208 VAC or 400 VAC or 480 VAC, 3 phase, 50/60 Hz. (Please specify at the time of order).

Average Charging Rate
8000 J/s, at rated Output Voltage.

Peak Charging Rate
9000 J/s at rated Output Voltage.

DC Power Rating
10kW at rated Output Voltage.

Standard Voltage Ranges
1 kV, 1.5 kV, 2 kV, 3 kV, 4 kV, 5 kV, 6 kV, 10 kV, 15 kV, 20kV, 30 kV, 40 kV, 50 kV.
All models continuously vary from 0 to 100% of rated voltage output.
Linear to within 1% of full scale. Accuracy 1% of rated.

Polarity
Available as fixed Positive or Negative, Please Specify.

High Voltage Assembly
Oil Insulated HV section with air insulation at voltages below 6kV

Output Connector/Cable

Output Voltage Connector Cable
1-6kV Amphenol 'HN' RG-8/U
> 6kV Proprietary DS 2214 80kV Rated

Input Connector
VDE, UL, CSA, approved.

Power Factor
Passive PFC 0.85 minimum

Efficiency
Better than 85%

Stored Energy
Less than 0.3 Joules all models.

Stability
0.2% per hour after 1 hour warm-up.

Pulse to Pulse Repeatability
+/- 1% to 1000 Hz standard
+/- 0.1% to 1000 Hz available

Temperature Coefficient
100 PPM per oC

Ambient Temperature
Storage: -40 to +85 oC
Operating: -20 to +45 oC

Humidity
10-90% Non-condensing

Protection
The power supply is protected against open circuits, short circuits, overloads and arcs.

Agency Approvals
Certification to EN60950 (pending)

Mechanical

19" rack (483mm) x 17"(432mm) x 8.72"(222mm)

Accessories
- Detachable 10 foot HV cable
- Operating manual

Options

Suffix-RFI Optional external filter which reduces conducted emissions to meet VDE0871/6.78 Class B.
Suffix-LH "Low Inhibit" - A + 10 to 15 volt (high) signal will allow power supply operation. A 0 to +1.5 (low) signal will inhibit the supply.
Suffix-EN "Low Enable" - A + 10 to 15 volt (high) signal will disable power supply operation. A 0 to +1.5 volt (low) signal will enable the supply.
Suffix-5V 0 to +5 volt voltage (0 to full-scale output)
Suffix-LP Latching overload protection
Suffix-RS Remote sense
Suffix-CT Optional internal contactor for OEM only (standard on L/S models)


Ordering Example

XR802L - 20kV - NEG - 400VAC - RS
Model   Voltage   Polarity   Input
Voltage
  Options

EMSseries ] GENseries ] ESSseries ] EMHPseries ] 500 series ] 402 series ] 203series ] [ XRseries ] LCseries ]


TDK Lambda ] Behlman ] Krohn Hite ] Unipower ] Suplitec Lineares ] Trek ] MDI ]


Suplitec - Suprimentos Técnicos Ltda E-Mail :
Rua Sena Madureira 495 ,  31340-000  Belo Hte - MG
Fone/Fax : +55-31-3498 1177  -   Fax : + 55-31- 3441 0841 Vendas : vendas@suplitec.com.br
Suporte Técnico : suporte@suplitec.com.br
Updated on : February 24, 2009 Comentários/Dúvidas : webmaster@suplitec.com.br